RECI W6 / S6 130W-160W CO2 Sealed Laser Tube. The Laser Tube product is ordering production, need 3 to 5 days of stock up time. High power rate, fast - speed cutting and small size Origin: Asia and Pacific Area China Quality standard: International H.

Classification: Machinery & Electronics Electr. Element 8541 Semiconductor devices; light - emitting diodes etc. Specifications for industrial CO2 laser tubes. 80mm (3.15) ± 2mm.

Maximum working current is 32mA. The running current must be kept below 30mA. The life span can reach 8,000 hours if the current is kept below 28mA. Rated power 135W and Maximum power 155W.

We will send a new one freely if the tube is broken during transit. Once received the laser tube, please check again at the first time. We need the damaged record from the courier as the proof before we send the new one free.

Output Power: Its output power can reach 155w. The production process of the tube is standardized, so the output power and output model are guaranteed. (For other laser tube manufacturers: can't provide this product) Long life span: We have catalyst plating in the inner wall of the laser tube.

No catalyst technique is used by other laser tubes manufacturers. High photoelectric conversion rate: The output power will decrease for less than 2w when the cooling water's temperature is 42?

Its heat productivity is lower than 100w tubes of other brands. Other brands: The output power decrease rapidly when the cooling water's temperature is 42? Appearance: The tube is sealed by metal material. No metal material is used by other manufacturers. Their tubes are handmade and need extra water cooling for front and rare mirrors. Tube frame: This is exclusive design for Reci laser tube. This frame is shockproof and makes sure the tube will not move during the transport. No frame is provided by other manufacturers.

Length: The length is only 1.65m. The length of other 150w tubes is 1.8m. 150mm must be projecting in the machine.

That costs more for machine sheet metal, package and transport. Reci W6 CO2 Laser Tube is featured as high power rate, good model, and fast - speed cutting and small size, which is used for the cutting of DIE cutting, thick Acrylic Board cutting.

High power cutting High photoelectric conversion rate: No compression type Water Chiller should be equipped. The output power will decrease for less than 1w when the cooling water's temperature is 42? Its heat productivity is lower than 60w tubes of other brands. Other brands: The output power decreases rapidly when the cooling water's temperature is 42?

Label Negative electrode container Output mirror Product number in metal terminal Tube Model Sample Laser spot with depth of 5mm. Installation Requirement Make sure to follow the operation instructions of model W6 as shown in the illustration. The dedicated power DY20 should be equipped.

The positive pole is in high voltage (The ignition voltage is 28kv). It may cause the following consequence when it is failed to follow the instruction: Arcing; the inner tube will be punctured by electricity and may cause water leakage. Water cooling: Using purified water; 3 to 5 liter / minute; water temperature: 10? The operating environment: temperature 2 - 40? The working current: test current is 29mA. The life span can reach 10,000 hours if the current is kept below 28mA. The ammeter indicating current must be connected to the negative electrode of the laser tube. When it is working under over - high current for long term, the negative pole will appear light yellow, and the life span will be reduced rapidly. To protect dust from going into the insulation sheath, please wrap it with plastic film.

Key Notes Do not clean the exterior surface of the output widow mirror with tools such as tampon; otherwise the output power will be seriously affected. The followings are the designated methods to clean up pollution in the exterior surface of window mirror: 1 When the mirror is polluted, do not turn on the laser. 2 Blow the mirror surface sideway with air blower. 3 Spray the pure alcohol on the mirror surface with sprayer. 4 Turn on the laser after the alcohol gets fully volatilized.

5 If the methods above don't work effectively, it is necessary to ask for the professional to use tampon with alcohol to clean the mirror surface from middle to edge. The best solution is to prevent the window from being polluted. Attention: It is forbidden to clean the mirror with acetone. The screw in the front and back ends of the laser tube is not allowed to be moved, otherwise the out power will be declined and even the tube may be scrapped. Put the acryl 300mm far away from output mirror, when testing the laser spot. Safety The laser beam is invisible light. Please wear protective glasses when debugging the laser. The positive pole is in high voltage. Pay attention to the security marks. Storage and Transportation Requirement Pour out cooling fluid in the event of storage and transportation, and cover the output terminal with a dust - proof plastic bag. The storage environment is 2 - 40? And the requested humidity is 10 - 60%. Pack the laser as in the original way. Important notes: it is requested to cement the sponge together with laser tube to prevent the tube vertically sliding during transportation.

The sponge in the side of output mirror must be 70mm beyond it, and the sponge in the side of reflecting mirror must be 50mm wider. How to check the laser? The laser power will reduce gradually while using. When the maximum power can't carve deep enough, please change the laser tube.

We need to exclude other reason of the problem. Firstly, make sure following things: Cooling - water flows well and bot hot or dirty. When water temperature is higher, laser's power will drop fast, or even explode the laser. At this time, change it or add more cooling water.

Secondly, make sure the mirrors, lens and light rought are all good. Thirdly, make sure the electrical power and fanners is working well. When the temperature of electrical power is higher, it will afect the laser. In fact, laser's power will reduce slowly.

When the laser is all right, light beam in the tube is pink - purple, when it's near to be finished, the light change to with. The company shall not take the responsibility from the 8th day. The replaced laser tube enjoys the quality guarantee as the new one from the manufacturing date. The company is not responsible for any damage and change of laser structures. From the 180th to the 300th days after manufactured, if the user follows the instructions and the power output happens to be lower than 85% of the rated power output, the company shall provide either repair or replace the laser tube with our special tube (depending on specific case) for free.

The quality assurance is invalidated to the special offered products or customized products. The user must follow the instructions for S2; otherwise the quality guaranteed assurance is invalidated. The matched power supply for each model must be equipped; otherwise the quality guaranteed assurance is invalidated. 1 The appearance, structure and certificate are in good condition.

2 The surface of output mirror is not polluted, cut or splitted. 33 The following features shall NOT appear. The exterior surface of the negative electrode container shall NOT in. The discharge area within the electrode container shall NOT.

The two phenomena are in direct proportion with the intensity of current flow and the usage of super-current. We mainly rely on this method to measure whether the laser is in over-high current state for long time. If this happens, we shall not provide guarantee for the laser. So the user must pay attention in case of losses. Please download the Quality Assurance for S-Series to know more information about Quality Feedback.

Wooden Box: There is total one wooden box. 3.15" x 65" L? 72.8" x 15.4" x 15.7 (1850mm x 390mm x 400mm). This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Other Healthcare, Lab & Dental". The seller is "pro-signsmaker" and is located in this country: CN. This item can be shipped worldwide.