CW-5200 series use an intelligent thermostat. Normally users do not need to adjust it. If it's really necessary, please refer to Operating status and parameters adjustment. Cooling water must be kept empty when cooling machine has been not in use for long or in transport. It is strictly forbidden to plug and run the cooler without feeding water.
Cooler should be placed in a well-ventilated, dry environment away from heat sources. Please keep at least 30cm from obstructions to the air outlet which is in the back of the cooler, and leave at least 10cm between obstructions and air inlets of two sides. To protect laser tubes, the radiator fan of cooler will suspend to work when water temperature is too low, and it will restart to run when water temperature rises back to accceptable range. To ensure good heat dissipating, please open the lid to clean the dirt regularly.
Working in cold north area, it is better to use noncorrosive antifreeze fluid. E1- Over high room temperature.
E2- Over high water temperature. E3- Over low water temperature. E4- Room temperature sensor failure.
E5- Water temperature sensor failure. When alarm occurs, the error code and the temperature will be alternately displayed.In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display. Remains until the alarm condition is eliminated. Flow alarm and output ports. In order to guarantee that the equipment will not be damaged when cooling water circulation is out of control, CW-5200series chillers possesses an unique low flow alarm protection. The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.
Energy saving, long working life and simple operation. Different models according to local voltage and frequency. With completed water flow and over high temperature alarm functions. Professional forced air-cooled radiator, high heat dissipating capacity and not easy to be blocked. Equipped with alarm output port, can quickly protect sensitive components. Multiple power specifications; CE approval; RoHS approval. Water is available for a long time used. Real-time temperature monitoring, accurate knowledge of heating devices working condition. High cost performance, low failure rate. 1400W cooling capacity; optional environmental refrigerant. ±0.3°C precisely temperature control. The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions. Multiple alarm functions: compressor time-delay protection, compressor overcurrentprotection, water flow alarm and over high / low temperature alarm. Optional heater and water filter. Compressor Power: 0.68KW, 0.93HP. Refrigerating Capacity: 5186Btu/h, 1.52KW, 1307Kcal/h.Refrigerant: R-22 / R-134a / R-410a. Inlet and Outlet: External F10mm brass connector. Protection: Over current protection for compressor, flow alarm, over temperature alarm.
1 × CW-5200DG Water Chiller Machine. 1 × Alarm Signal Output Plug. This item is in the category "Business & Industrial\HVAC & Refrigeration\Other HVAC & Refrigeration". The seller is "machine-bi" and is located in this country: CN.This item can be shipped worldwide.